Flow Sensors

Need Assistance?

Your local expert is here to help.

Ran de Silva
Engineering Manager
rdesilva@epsglobal.com
+44 118 9473622

Quantity breaks available. View Pricing Table

Pricing Table

The IST AG FS2 flow sensors are applicable in gas and offer excellent long-term stability. In addition to measuring flow rates, the FS2 gas flow sensor is able to detect flow direction with outstanding sensitivity.The IST AG FS2 flow sensors are optimal for measuring gas flow and direction.
FS2 - Optimal for measuring gas flow and direction
https://www.epsglobal.com/getmetafile/7fc3380f-d4b7-45f5-a85b-3949ca5b5e1d/FS2?maxsidesize=400
<p>The IST AG FS2 flow sensors are applicable in gas and offer excellent long-term stability. In addition to measuring flow rates, the FS2 gas flow sensor is able to detect flow direction with outstanding sensitivity.</p> <p>The IST AG FS2 flow sensors are optimal for measuring gas flow and direction.</p>
FS2
FS2
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Quantity breaks available. View Pricing Table

Pricing Table

The IST AG MicroFlowSens (MFS) technology was developed for fast flow measurements. Due to the membrane system, the thermal mass is reduced to the minimum resulting in a very fast response time and low power consumption. In addition to measuring flow rates, the MicroFlowSens offers an outstanding sensitivity and is able to detect flow direction. The MFS flow sensor is optimal for limited space system integration and is available as integrated sensor on a PCB.
MicroFlow - High performance over a wide dynamic range
https://www.epsglobal.com/getmetafile/d031454d-2605-4637-a656-301d61f97ee9/DFMFS02?maxsidesize=400
<p>The IST AG MicroFlowSens (MFS) technology was developed for fast flow measurements. Due to the membrane system, the thermal mass is reduced to the minimum resulting in a very fast response time and low power consumption. In addition to measuring flow rates, the MicroFlowSens offers an outstanding sensitivity and is able to detect flow direction. The MFS flow sensor is optimal for limited space system integration and is available as integrated sensor on a PCB.</p>
DFMFS02
DFMFS02
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Quantity breaks available. View Pricing Table

Pricing Table

The IST AG Out of Liquid flow sensor utilizes the reliable and proven thermal mass flow measuring principle and is specially developed for flow applications with aggressive liquid media. The sensor provides the flexibility of easy adaption in an application and at a lower cost. Measuring flow directly in a liquid channel has proven a difficult task without dramatically shortening the lifetime and damaging the sensor. The Out of Liquid flow sensor offers the possibility to create no-flow / flow switches. It also offers the possibility of an extremely accurate measurement. A heater and a temperature sensor chip, both with backside metallization, are soldered on the stainless steel flow channel providing an excellent thermal contact with the liquid without being in direct contact with it, meaning even aggressive liquids can be measured easily with this sensor.
Out of Liquid - Optimal for flow applications in aggresive liquids
https://www.epsglobal.com/getmetafile/7ee04947-81b5-4034-a26d-1deab233e4ca/DFoolE0?maxsidesize=400
<p>The IST AG Out of Liquid flow sensor utilizes the reliable and proven thermal mass flow measuring principle and is specially developed for flow applications with aggressive liquid media. The sensor provides the flexibility of easy adaption in an application and at a lower cost. Measuring flow directly in a liquid channel has proven a difficult task without dramatically shortening the lifetime and damaging the sensor. The Out of Liquid flow sensor offers the possibility to create no-flow / flow switches. It also offers the possibility of an extremely accurate measurement. A heater and a temperature sensor chip, both with backside metallization, are soldered on the stainless steel flow channel providing an excellent thermal contact with the liquid without being in direct contact with it, meaning even aggressive liquids can be measured easily with this sensor.</p>
DFoolE0
DFoolE0
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Quantity breaks available. View Pricing Table

Pricing Table

The IST AG FS7.4W gas flow sensor has been developed for applications with temperatures up to 400 °C. The design of the FS7.4W is based on the FS7 design which offers a symmetrical heater that enhances sensitivity. The FS7.4W flow sensor is applicable in gas and offers excellent long-term stability. The small thermal mass of the FS7.4W sensor provides a fast response time.The IST AG FS7.4W flow sensors are optimal for measuring gas flow in various flow applications.
FS7.4W - Optimal for applications requiring a high sensitivity up to +400 °C
https://www.epsglobal.com/getmetafile/3c27cbe2-bfa5-4208-b873-0d8028ac88ae/FS74W?maxsidesize=400
<p>The IST AG FS7.4W gas flow sensor has been developed for applications with temperatures up to 400 °C. The design of the FS7.4W is based on the FS7 design which offers a symmetrical heater that enhances sensitivity. The FS7.4W flow sensor is applicable in gas and offers excellent long-term stability. The small thermal mass of the FS7.4W sensor provides a fast response time.</p><p>The IST AG FS7.4W flow sensors are optimal for measuring gas flow in various flow applications.</p>
FS7.4W
FS7.4W
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Quantity breaks available. View Pricing Table

Pricing Table

The IST AG FS7 thermal mass flow sensors are the successors of the FS5 flow sensors and exhibit a symmetrical heater design and enhanced sensitivity. The FS7 flow sensor is applicable in gas and offer excellent long-term stability. The small thermal mass of the FS7 sensor provides a fast response time. Additionally, the standard FS7 sensor is also available with a housing which is easily implemented into various applications.The IST AG FS7 flow sensors are optimal for measuring gas flow in various flow applications.
FS7 - Optimal for applications requiring a high sensitivity up to +150 °C
https://www.epsglobal.com/getmetafile/be6e2aad-459e-45ae-a4d0-ab720fa8cb94/FS7?maxsidesize=400
<p>The IST AG FS7 thermal mass flow sensors are the successors of the FS5 flow sensors and exhibit a symmetrical heater design and enhanced sensitivity. The FS7 flow sensor is applicable in gas and offer excellent long-term stability. The small thermal mass of the FS7 sensor provides a fast response time. Additionally, the standard FS7 sensor is also available with a housing which is easily implemented into various applications.</p><p>The IST AG FS7 flow sensors are optimal for measuring gas flow in various flow applications.</p>
FS7
FS7
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Quantity breaks available. View Pricing Table

Pricing Table

The SFS is IST AG's first flow sensor based on silicon technology. It is operated according to the calorimetric principle and can therefore detect not only the flow velocity but also the flow direction.The symmetrical design of the SFS flow sensor allows an easy interpretation and evaluation of the measurement signal. The sensor can be used in different gases. It is characterized by a high sensitivity, a very fast response time and an extremely low energy consumption.IST AG offers the full range of cooperation, from support with the customer's system integration to pre-assembled, customer-specific partial solutions and a complete solution tailored to the customer's application.
SFS01 - For the ultra-fast measurement of low flow rates
https://www.epsglobal.com/getmetafile/599d66be-0ef7-462f-80b6-d405f456d4fa/SFS01?maxsidesize=400
<p>The SFS is IST AG's first flow sensor based on silicon technology. It is operated according to the calorimetric principle and can therefore detect not only the flow velocity but also the flow direction.</p><p>The symmetrical design of the SFS flow sensor allows an easy interpretation and evaluation of the measurement signal. The sensor can be used in different gases. It is characterized by a high sensitivity, a very fast response time and an extremely low energy consumption.</p><p>IST AG offers the full range of cooperation, from support with the customer's system integration to pre-assembled, customer-specific partial solutions and a complete solution tailored to the customer's application.</p>
SFS01
SFS01
IST
https://www.epsglobal.com/getmetafile/8904bb79-a7f0-4831-ad36-2920bce52389/IST

Showing 6 of 6 results

Showing 1 - 6 of 6 results

Need Help?

We have local language and currency support in each of our 28 locations, ensuring you always have access to friendly customer support to deliver your hardware solutions regardless of your location.

Request a callback from our experts